Device description¶
General information¶
| Functions | Description | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Measured parameters | Analog Input, 0...20 mA / 4...20 mA (RMS-MADC-XXX-A) or 0...10 V (RMS-MADC-XXX-V) | ||||||||||||||||||
| Accuracy (humidity & temperature) |
Temperature: ±0.5 °C @ 25 °C / ±1 °C @ 0…70 °C / ±3.5 °C @ other temperature range Relative humidity: ± 3 %rh @ 25 °C |
||||||||||||||||||
| Dimensions | 83 x 29 x 29 mm | ||||||||||||||||||
| Housing material | ABC | ||||||||||||||||||
| Weight | 100 g | ||||||||||||||||||
| Power Supply | The mini data logger has one 3.6 V lithium thionyl chloride AA battery. The power supply of this battery suffices to carry out measurement and data storage and to operate the wireless interface. Note on the batteries: The AA batteries are lithium thionyl chloride batteries available in the industrial trade. All RMS input modules are designed for this type of battery. Only batteries of the same type or with identical characteristic values may be used as replacement batteries. Type of Battery \ |
Article \ | RMS-BAT (ER14505M, multiple manufacturer - see website: accessories) \ | \ | --- \ | --- \ | \ | Type \ | Li-SOCl2 \ | \ | Capacitance \ | ~2200 mAh \ | \ | Voltage \ | 3.6 V \ | \ | Dimensions \ | AA (H: 50.3 mm, D: 14.55 mm) \ | |
| Article | RMS-BAT (ER14505M, multiple manufacturer - see website: accessories) | ||||||||||||||||||
| Type | Li-SOCl2 | ||||||||||||||||||
| Capacitance | ~2200 mAh | ||||||||||||||||||
| Voltage | 3.6 V | ||||||||||||||||||
| Dimensions | AA (H: 50.3 mm, D: 14.55 mm) | ||||||||||||||||||
| Digital interface | The logger is operated completely via the wireless interface. |