Sensors and Probes¶
Rotronic offer the following sensors and probes:
- Digital HCD-Sx for relative humidity and temperature measurement.
- Digital HCD-IC for industrial relative humidity and temperature measurement.
- Digital PCD-S for differential pressure measurement.
- Digital CCD-S for indoor air quality (IAQ) CO2 measurement.
- Digital TCD-S for temperature measurement.
- Analogue CCA-S-20X & CCA-S-20X-SET for incubator CO2 measurement.
- Analogue Temperature Sensors.
As a world-leading manufacturer of humidity measurement instruments, Rotronic is fully aware of its responsibility to offer instruments that can withstand the harshest operating conditions, while remaining user-friendly and requiring minimal maintenance. At the same time we urge our users to ensure continued performance within specification of the measurement instruments at the expense of a small amount of effort. The following checklist is provided as a guide.
-
Analyze the environment in which the humidity probe is used. What suspended substances and/or chemicals exist and in approximately what concentration?
-
Install the probe at a place representative of the measured climate with good airflow across the sensor.
-
Choose the right filter. Measurement is fastest without a filter. For air velocities higher than 3 m/s, however, a filter must be used. The filter protects the sensor up to airflow velocities of 40 m/s, depending on the filter type used. Suitable filters must also be used in the case of contaminants/pollutants and in harsh environmental conditions. Inspect and replace the filter more frequently in harsh operating conditions. Filters can be cleaned in an ultrasonic bath. However, always keep a new filter set in stock.
-
For calibrations , use one of our calibration services or the SCS-certified humidity standards. This will ensure your calibration is traceable to national standards, as a minimum. Rotronic recommend regular calibration at least every 6 to 12 months.
Rotronic offers a range of theory details on the website:
- Relative humidity and temperature: https://www.rotronic.com/en-ch/humidity_measurement-feuchtemessung-mesure_de_l_humidite/parameter-humidity-mr/.
- CO2:https://www.rotronic.com/en-ch/humidity_measurement-feuchtemessung-mesure_de_l_humidite/parameter-co2-mr.
- Flow:https://www.rotronic.com/en-ch/humidity_measurement-feuchtemessung-mesure_de_l_humidite/parameter-flow-mr.
- Dew point:https://www.rotronic.com/en-ch/humidity_measurement-feuchtemessung-mesure_de_l_humidite/parameter-dew-point-mr.
- Differential pressure:https://www.rotronic.com/en-ch/humidity_measurement-feuchtemessung-mesure_de_l_humidite/parameter-differential-pressure-mr.
- ATEX:https://www.rotronic.com/en-ch/humidity_measurement-feuchtemessung-mesure_de_l_humidite/parameter-atex-mr.