Skip to content

Update from >V2.0 to V2.4.0 of the RMS Software

Important:
As soon as the Rotronic Monitoring System >V2.0.0 has been uploaded, please update all RMS-GW devices with the latest firmware version: Update Firmware.
Please reach out to Rotronic for more details: [email protected].

Installing Multiple Instances.

Follow these guidelines for the upgrade of a software version >2.0 to the V2.4.0. These guidelines work for a single server (application and database) as well as for two servers (one for the application and another one for the database).

Prerequisites:

  • A previous version of RMS is already installed (>V2.0).
  • The current version is hosted in IIS on the site “Default Web Site” and named “RMS” and “wService”.

  • The new RMS Files are unzipped in the folder “C:\inetpub\wwwroot\RMS\240.23070”.

  • The “connection.config” file contains the correct information for the database connection.

IMPORTANT: as soon as the prerequisites above are not met, additional adaptations are necessary!!!

Step 1 Unzip the new version (password: Rotronic123):
update V240 14
Copy it into a folder with the version number parallel to the currently installed version: "C://inetpub/wwwroot/rms/{version}".
update V240 15
Step 2 Open SQL Server Management Studio:
update V240 16
Login to the SQL Server as ADMIN or SA user:
2_2.3.0
Step 3 Create a backup of the RMS database, right click on the rms database>Tasks>Back Up...
3_2.3.0
Select a full backup to the disk and click on OK:
4_2.3.0
Ensure that the tick box is selected to verify the backup when finished, click on OK:
5_2.3.0
Select the backup destination:
6_2.3.0
7_2.3.0
The database should then be backed up, click on OK.
update V240 17
Step 4 Update the database tables using the "Rotronic-Rms-Tables". Via the SQL Server Management Studio, click on "open file" and double click on the folder to update.
update V240 18
update V240 19
The following data will be shown and click on execute. Please check before execute in which database you will run this script. The rms database should be shown in the left top field!
10_2.3.0
Once executed, the following screen should be visible:
11_2.3.0
Step 5 Update the RMS SQL indices,  via the SQL Server Management Studio, click on "open file" and select the required SQL indices.
Please check before execution in which database you will run this script. The rms database should be shown in the left top field!
Check what version of MS SQL is running on the server.
Based upon the MS SQL version, double click on the either RMS_SQL_Indices or RMS_SQL_Indices (SQL 2014 or older) to upgrade and execute it.
12_2.3.0
The following overview will appear:
13_2.3.0
Once executed, the following screen should be visible (take this print screen for validation purposes):
14_2.3.0
Step 6 In the 240.23070 folder, install the .Net Framework V4.8.0 or newer, double click on the file npd480-WEB.exe:
update v240 20
When prompted click on continue to install the .NET framework or close if it is already installed.
.NET framework already installed, close the window and please move to the next step.
update v240 21
Installation of the .NET framework, click on Install.
14_1.3.1
The installation will start:
15_1.3.1
Once completed, the following screen will appear:
16_1.3.1
A server restart is required:
17_1.3.1
Step 7 In the 240.23070 folder, update the connections.config file of the new software installation based upon the settings of the current software installation.
update v240 22
Edit, if required, the connection string (via Notepad) if the in connections.config in folder C:\inetpub\wwwroot\RMS\240.23070\ServiceManager:
- Data Source,
- Initial Catalog,
- User ID,
- Password.
The existing connections.config data can be found in C:\inetpub\wwwroot\RMS\xxxxx\wPage.
18_2.3.0
Here is the overview of the old and new files:
17_2.3.0
Step 8 Test the connection to the database, by double clicking on the TestDatabase.cmd command:
update v240 23
If the following screen appears, return to step 5 and execute the "Rotronic-RMS-Tables":
clip0116
The following screen should be shown if the test is successful:
20_2.3.0
Step 9 \ Important Note
If you update from If you update from >V2.0.0 or higher, use the Update2xTo240.cmd \
\ --- \
update v240 24
Important Note
If you update from If you update from >V2.0.0 or higher, use the Update2xTo240.cmd
Step
10
Open the Update2ToV240.cmd file with notepad and check to ensure that the wPageName, wServiceName and ManagerInstance are all correct.
IMPORTANT: the wPage, wServiceName can be found in the IIS:
wservice and wpage
The correct details are listed below in yellow:
update v240 25
Step 11 Open the RmsServiceManager.exe.config, in the ServiceManager file with notepad and check to ensure that the port = 8091:
update v240 26
Open the NLog.config, in the ServiceManager file with notepad and check to ensure that the path is set to rms_files:
update v240 27
Open the web.config, in the wPage file with notepad and check to ensure that the localhost:8091:
update v240 28
update v240 29
Open the web.config, in the wService file with notepad and check to ensure that the localhost:8091:
update v240 30
Open the NLog.config, in the wService file with notepad and check to ensure that the path is set to rms_files:
update v240 32
Step 12 Right click on the Update2ToVxx.cmd and run as administrator to run the update command and follow the steps in the script:
update v240 33
IMPORTANT: should the URL (C:\inetpub\wwwroot\rms\240.23070) not be correct, then the URL needs to be changed within the Update2XT0240.cmd file via right click and edit.
update v240 34
update v240 35
update v240 36
update v240 37
update v240 38
update v240 39
Step 13 Recycle Application Pool .NET V4.5 (in IIS Manager>Application Pools>Recycle).
34_2.3.0
Step 14 Test to see if the website and the webservice are running: Software Installation Testing.
If the following screen appears, simply refresh the URL:
35_2.3.0
The following print screen should appear:
36_2.3.0
Step 15 If additional fonts are required: RMS V2.1 Add the Help Menu and Report Fonts.
Step 16 Update the Documentation path in the RMS software accordingly. The update created a new folder. The software update has created a new folder. We recommend either leaving the old folder as it is or integrating everything into the new one. If background images, layouts, etc. are used in the software, they must be copied from the old folder to the new one.
Log into RMS and select Tools>Setup>System:
41_1.3.1
Update the documentation path:
42_1.3.1
Step 17 Once the software updated, ensure that a new license key is also added: Update your License Code.

Update date: 24.07.2023.